CO2 Gas Sensor for OEM / Biotech

CO2 gas sensors to control CO2 levels in environmental incubators is crucial in the fields of Molecular Biology, Tissue Culture, Cell Biology, Protein Biochemistry and Immunochemical. Optimal carbon dioxide conditions are maintained using non-dispersive infrared (NDIR) CO2 gas analyzers in cell growth applications.
Fast CO2 gas detector recovery after an inner door opening, is achieved through a CO2 injection sequence for rapid return to the CO2 gas monitor set point. Independent regulation of CO2 gas levels provide for optimum growth conditions to meet the stringent requirements of today's cell and tissue culture experiments.

CO2 gas monitoring is also critical in poultry incubators as the embryo ages.
The oxygen demand increases rapidly as more carbon dioxide is given off to the environment. Carbon dioxide levels above 0.5% lower hatchability slightly, levels above 1.0% CO2 reduce hatchability significantly, and levels above 5.0% CO2 are lethal. Adequate air exchange rates need to be balanced with CO2 levels along with humidity content in the incubator to ensure safe and healthy development of the poultry embryos. 
                                                                                                                                                                                                      Areas of Application: 
Tissue Culture Incubators and Poultry Incubators.
 
*Notes: all the DIGITAL models listed in the section below require an input power of 12VDC. The 12VDC ANALOG units have a 0-1 volt output and a 4-20mA current loop output, except where indicated. The 115/230VAC ANALOG units have a 0-5V output and a 4-20mA current loop output.
 SKU #
             030546
 030545
 030708             
 030390-20
 030602-15
 030602-20                        030338
 030715       
 Range
             
 0-20%*
 0-20%*
 0-20%       %
 0-20%
 0-15%
 0-20%
                 0-1%
 0-2%
 Data/Spec Sheet
                 
 2015S-3N.pdf                            
                         2156-R1.pdf
 2156-R2.pdf
 Other
                 
 *Range is user adjustable, 0-1V analog out
 *Range is user adjustable, 0-1V analog out
 No switches and no analog output
                                         
 Remote gas cell, no 4- 20mA loop
 Low-Profile terminal block/90° hose barb
 Low-Profile terminal block/90° hose barb
                                                                           LED display, remote gc, audible alarm, 2 relays
 LED display, remote gc, audible alarm, 2 relays
 
 Model
 DIGITAL, 16-BIT SPI
 2005SPI-2
 2015SPI-3
 2015SPI-3N
 ANALOG, 12VDC
 2007DHH-R
 2008SDH-P 15%
 2008SDH-P 20%
 ANALOG, 115/230VAC
 2156-R 1%
 2156-R 2%
 Sensor Type
                 
 Diffusion Head
 Sample Draw
 Sample Draw
              
 Diffusion Head
 Sample Draw
 Sample Draw
             Diffusion Head
 Diffusion Head